Abstract
Background: Maintaining thermal stability in neonates remains a clinical challenge. Conventional resistive heat warmers (RHWs) may cause localized overheating, while large-surface warmers have been proposed as a safer alternative. Objective: The objective of this study was to compare surface temperature stability and heat flux characteristics of test objects exposed to a conventional resistive heat warmer (RHW) and a prototype large-surface warmer, using a regulatory reference test methodology for incubators and radiant warmers. Methods: Five calibrated Fluke Corporation test objects were placed on a pre-warmed mattress and exposed to each heating system. Both systems were evaluated across six servo-controlled temperature settings ranging from 36.0 to 37.0 °C. Surface temperature and heat flux at the upper surfaces of the test objects were recorded at 15-second intervals over a 60-minute period. Theoretical radiant heat flux requirements were calculated using the Stefan–Boltzmann law. Collected data were analyzed using descriptive statistics and independent t-tests to assess differences between the two warming modalities. Results: The RHW delivered heat flux values approximately 6–7 times higher than those measured under the large-surface radiant warmer (p < 0.001), with substantially greater temporal variability. In several settings, RHW heat flux exceeded the calculated theoretical requirements. In contrast, the large-surface radiant warmer maintained lower, more stable, and more uniform surface temperatures across all test objects. Both systems complied with the applicable standard thermal performance criteria. Conclusion: The prototype large-surface radiant warmer demonstrated gentler and more consistent heat delivery compared with the RHW, supporting its potential as a safer thermal support method in neonatal care. Continuous heat flux monitoring may provide an additional indicator of thermal readiness and stability during neonatal warming.
| Original language | English |
|---|---|
| Pages (from-to) | 81-89 |
| Journal | New Armenian Medical Journal |
| Volume | 20 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - May 2026 |
Keywords*
- heat flux
- neonatal warming
- radiant warmer
- servo control
- thermal safety
Field of Science
- 3.2 Clinical medicine
- 2.6 Medical engineering
Publication Type*
- 1.1. Scientific article indexed in Web of Science and/or Scopus database
ASJC Scopus subject areas
- General Medicine
Fingerprint
Dive into the research topics of 'Comparison of Radiant Heat Flux from a Large-Surface and Conventional Neonatal Warmer Using Standardized Black Body Placement'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver