The Stream Device-A Retrospective Review of 51 Cases

Kārlis Kupčs, Patrīcija Sproģe, Katrina Kupca, Bhogal Pervinder (Corresponding Author)

Research output: Contribution to journalArticlepeer-review

10 Downloads (Pure)

Abstract

Mechanical thrombectomy is the gold-standard treatment for patients that have suffered large-vessel occlusion (LVO) stroke. Various different stent-retrievers, aspiration catheters, and techniques have been developed to perform this procedure. We present our initial results regarding the Stream device. Materials and Methods: We performed a retrospective review of a prospectively maintained database at our high-volume centre to identify all patients treated with the Stream device between February 2021 and January 2023. We recorded baseline demographics, NIHSS, ASPECT scores, eTICI scores, complications, and 90-day mRS. Results: We identified 51 patients, 49.0% of whom were male (n = 25), with a median age of 73 (range: 51–89) and a median NIHSS score of 17 (range 4–22), and 68.6% received IV tPA. The median ASPECT score was 10 (range 6–10). Hyperdense clots were seen in 34 cases (66.7%), with a mean clot length of 12 ± 6.2 mm (range 2–26 mm). Clots were located in the anterior circulation in 49 patients. The standard Stream device was used in 78.4% of cases, with Stream 17 being used in 19.6% of cases. The FPE was observed in 25.5% of cases (n = 13), with the mFPE being seen in 31.4% of cases (n = 16). A final eTICI score of ≥2b was achieved in 90.2% of cases (n = 46), and eTICI 2c/3 was seen in 84.3% of cases (n = 43). Furthermore, 24 h CT scans showed that the median ASPECT score was 8 (range 0–10). Good functional outcomes at 90 days (mRS ≤ 2) were achieved in 21.6% of cases (n = 11). Conclusions: The Stream device shows acceptable rates of FPE and mFPE compared to existing devices. Further larger studies are required alongside an understanding of the optimal technique for this device’s use.

Original languageEnglish
Article number6384
JournalJournal of Clinical Medicine
Volume12
Issue number19
DOIs
Publication statusPublished - 6 Oct 2023

Keywords*

  • stream device
  • mechanical thrombectomy
  • ischaemic stroke

Field of Science*

  • 3.2 Clinical medicine

Publication Type*

  • 1.1. Scientific article indexed in Web of Science and/or Scopus database

Fingerprint

Dive into the research topics of 'The Stream Device-A Retrospective Review of 51 Cases'. Together they form a unique fingerprint.

Cite this